INTRODUCTION AND APPLICATIONS
CDSM2 series moulded case circuit break er is one o f new typ e break ers whi ch this co mpany
adopts international advanced design,manufacture technology to develop,The rated insulating
volta ge is 9 50V.Suit
able f or AC 50H z(60H z).ra ted working voltage 690v or below,rated working
current is 12.5 to 630A of circuit.and use in distrbuting electric energy.Non-frequ ent makin g
and breaking in the normal conditions and protecting when circuit and installation are overload,
short citcuit and lacking voltage.Rated shell-rack and the breaker which current is under 400A,
take protect effect when mousecage motor s non-frequent start.,brea
-
king off working and
protecting overload,short circuct and lacking voltage.
CLASSIFICATION OF MCCB
Installation type of MCCB:MCCB are suiable for vertical or harizontal installation.
According to use of MCCB:Distribution circuit protection type,motor protection type;
Accor ding t o conn ectio n way: Front panel connection,Back panel connection,plug-in connection;
According to operation way:for direct handle operating,for external rotary handle operating,for
motor operation;
Accrd ing to ov erloa d relea se type :magnetic release(only instantaneous)the modynamic magnetic
type(dual)
Accrding to number of poles:Two poles,Three ploes,Four poles;
The neutral ploe(N pole)of four ploe MCCB has four types;
TypeA:No overload release on N pole,which is making at the time;not closing and opening
with the other three poles.
TypeB:No overload release on N pole.which closing and opening with the other three poles.
TypeC:with overload release on N pole.which closing and opening with the other three poles.
TypeD:with overload release on N pole.which making all time:not closing and opening with the
other three poles.
MAIN TECHNICAL SPECIFICATIONS
|
| Type |
Rated
Current(A) |
Pole
number |
Rated
Insultating
Voltage
(V) |
Rated
Opreating
Voltage
(V) |
Arcing-
Over
Distance
(mm) |
Ultimate Short
Circuit Breaking
Capacity
(KA) |
Servues Short
Circuit Breaking
Capacity
(KA) |
Operation performance |
| ON |
OFF |
| CDSM2-100D |
12.6,16,20,25,32,40,50,63,80,100 |
three
four
Pole |
950 |
<690 |
0 |
18 |
18 |
1500 |
8500 |
| CDSM2-100N |
25 |
25 |
| CDSM2-100H |
70 |
70 |
| CDSM2-100L |
150 |
150 |
| CDSM2-160D |
16,20,25,32,40,50,63,80,100,125,160 |
25 |
25 |
1000 |
7000 |
| CDSM2-160N |
36 |
36 |
| CDSM2-160H |
70 |
70 |
| CDSM2-160L |
150 |
150 |
| CDSM2-250D |
160,180,
200,225,
250 |
25 |
25 |
1000 |
7000 |
| CDSM2-250N |
36 |
36 |
| CDSM2-250H |
70 |
70 |
| CDSM2-250L |
150 |
150 |
| CDSM2-400D |
200,225,
250,300,
315,400 |
35 |
35 |
1000 |
4000 |
| CDSM2-400N |
45 |
45 |
| CDSM2-400H |
70 |
70 |
| CDSM2-400L |
150 |
150 |
| CDSM2-630D |
315,400,
400,500,
600,630 |
35 |
35 |
1000 |
4000 |
| CDSM2-630N |
45 |
45 |
| CDSM2-630H |
70 |
70 |
| CDSM2-630L |
150 |
150 |
|
| TRIP CHARACTRISTIC OF MCCB |
| |
|
|
|
| |
|
|
|